Description

  •    Universal input configurable from the faceplate
  •    Acquisition of the input signal every 120msec ; resolution 30000steps
  •    Two control outputs: relay, logic or analogue with Heat/Cool function
  •    3 configurable alarms
  •    2 analogue outputs (setpoint retransmission)
  •    2 digital inputs with configurable function
  •    Auxiliary input for C.T. or remote setpoint
  •    Heater Break or shortcircuit probe alarm
  •    Self and Auto-tuning, Soft-start, Local/Remote setpoint, Auto/Man
  •    12 (16) steps arranged in max. 4 programs
  •    Second SP retransmitted to a slave controller, with same time-base
-

Description

  •    Operator interface with large LCD display and three configurable bar graph
  •    Scrolling diagnostics messages, configurable, in the selected language
  •    Easy, guided configuration, copy/ paste parameters even with power off
  •    Preventive maintenance with energy counters (kWh) and load switching
  •    32 function block applications
  •    8 math application blocks
  •    Timer, setpoint and algorithm programmer for controlling motorized valves
  •    Advanced tuning of control parameters
  •    Different password levels
  •    2 universal inputs configurable for thermocouples, resistance thermometers, linear inputs
  •    2 PID control loop
  •    2 setpoint programmers (128 steps in 16 programs)
  •    Relay, logic, isolated analog outputs
  •    Up to two CT inputs for interrupted load diagnostics
  •    RS485 serial communication in Modbus RTU
  •    Removable faceplate for immediate replacement
  •    Sampling time 60 ms

Description

  •    Operator interface with large LCD Display
  •    Scrolling diagnostics messages, configurable, in the selected language
  •    Easy, guided configuration, copy/paste parameters even with power off
  •    Preventive maintenance with energy counters (kWh) and load switching
  •    32 function block applications
  •    8 math application blocks
  •    Timer, setpoint and algorithm programmer for controlling motorized valves
  •    Advanced tuning of control parameters
  •    Different password levels
  •    2 Universal input configurable for thermocouples, resistance thermometers, linear inputs
  •    2 PID control loop
  •    2 setpoint programmers (128 steps in 16 programs)
  •    Relay, logic, isolated analog outputs
  •    Up to two CT inputs for interrupted load diagnostics
  •    RS485 serial communication in Modbus RTU
  •    Removable faceplate for immediate replacement
  •    Sampling time 60 ms


Description

  •    Universal input configurable from the faceplate
  •    Accuracy 0,2% f.s.
  •    Two control outputs: relay, logic or analogue with Heat/Cool function
  •    3 configurable alarms
  •    2 analogue outputs
  •    2 digital inputs with configurable function
  •    Auxiliary input for C.T. or remote setpoint
  •    Heater Break or shortcircuit probe alarm
  •    Self-tuning, Soft-start, Auto-tuning, Man/Auto, Bumpless, Setpoint, Locale/Remoto
  •    Function multiset, rampa di set, timer


Description

  •    Universal input configurable from the faceplate
  •    Acquisition of the input signal every 120msec ; resolution 30000steps
  •    Two control outputs: relay, logic or analogue with Heat/Cool function
  •    3 configurable alarms
  •    2 analogue outputs (setpoint retransmission)
  •    2 digital inputs with configurable function
  •    Auxiliary input for C.T. or remote setpoint
  •    Heater Break or shortcircuit probe alarm
  •    Self and Auto-tuning, Soft-start, Local/Remote setpoint, Auto/Man
  •    12 (16) steps arranged in max. 4 programs
  •    Second SP retransmitted to a slave controller, with same time-base


Description

  •    Universal input configurable from the faceplate
  •    Acquisition of the input signal every 120msec ; resolution 30000steps
  •    Two control outputs: relay, logic or analogue with Open/Close valve function
  •    3 configurable alarms
  •    2 analogue outputs (setpoint retransmission)
  •    2 digital inputs with configurable function
  •    Auxiliary input for valve position potentiometer feedback
  •    Heater Break or shortcircuit probe alarm
  •    Self and Auto-tuning, Soft-start, Local/Remote setpoint, Auto/Man
  •    Multiset function, timer set ramp
Temperature Controller
-

Description

  •    Universal input configurable from the faceplate
  •    Acquisition of the input signal every 120msec ; resolution 30000 steps
  •    Two control outputs: relay, logic or analogue with Open/Close valve function
  •    3 configurable alarms
  •    2 analogue outputs (setpoint retransmission)
  •    2 digital inputs with configurable function
  •    Auxiliary input for valve position potentiometer feedback
  •    Heater Break or shortcircuit probe alarm
  •    Self and Auto-tuning, Soft-start, Local/Remote setpoint, Auto/Man
  •    Multiset function, timer set ramp


Description

  •    Universal input configurable from the faceplate
  •    Acquisition of the input signal every 120msec ; resolution 30000steps
  •    Two control outputs: relay, logic or analogue with Heat/Cool function
  •    3 configurable alarms
  •    2 analogue outputs (setpoint retransmission)
  •    2 digital inputs with configurable function
  •    Auxiliary input for C.T. or remote setpoint
  •    Heater Break or shortcircuit probe alarm
  •    Self and Auto-tuning, Soft-start, Local/Remote setpoint, Auto/Man
  •    Function multiset, rampa di set, timer


Description

  •    Operator interface with large LCD display and three configurable bar graph
  •    Scrolling diagnostics messages, configurable, in the selected language
  •    Easy, guided configuration, copy/paste parameters even with power off
  •    Preventive maintenance with energy counters (kWh) and load switching
  •    32 function block applications
  •    8 math application blocks
  •    Timer, setpoint and algorithm programmer for controlling motorized valves
  •    Advanced tuning of control parameters
  •    Different password levels
  •    2 universal inputs configurable for thermocouples, resistance thermometers, linear inputs
  •    2 PID control loop
  •    2 setpoint programmers (128 steps in 16 programs)
  •    Relay, logic, isolated analog outputs
  •    Up to two CT inputs for interrupted load diagnostics
  •    RS485 serial communication in Modbus RTU
  •    Removable faceplate for immediate replacement
  •    Sampling time 60 ms
800V Controller for Motorized Valves
Industrial Thermo Products
Home            Our Products             Line Card           Technical Info.          Contact Us   
ITP - Industrial Heaters
Gefran Temperature Controls - Performance Models
(Configurable single and double loop controller & set point programmer)  
Temperature Control
850 1/16 DIN Double PID Temperature Controller
Download the datasheet for this controller:
Temperature Controller
800 Controller
Download the datasheet for this controller:
Temperature Controller
Download the datasheet for this controller:
Temperature Control
1650 PID 1/8 DIN Double Temperature Controller
Download the datasheet for this controller:
1600 - 1800 Controller
Download the datasheet for this controller:
Controller
1600V - 1800V Controllers for Motorized Valves
Download the datasheet for this controller:
Controllers for Motorized Valves
Controllers for Motorized Valves
Programmer Controller
Programmer Controller
1600P - 1800P Programmer-Controller
Download the datasheet for this controller:
Temperature Control
800P Programmer-Controller
Download the datasheet for this controller:
Temperature Control
1850 PID 1/4 DIN Double Loop Temperature Controller
Download the datasheet for this controller:
For high-demand control applications, where the controller has to think before acting.
Industrial Thermo Products
Need more information?  Contact Us
©2020 Industrial Thermo Products, All Rights Reserved
     Call Us Today!  (847) 398-8600                                                                                               itp@industrialthermo.com
ITP, a long-term partner collaborating on lasting solutions! ®